Dynamic state assessment of the water turbine with the power of 600 kW

The article discusses the results of experimental studies to assess the dynamic state of the turbine set with the Kaplan turbine. The dynamic assessment was made on the basis of appropriate standards, based on the measurement results of selected parameters of vibration, which have been measured for several states of the machine load. In addition, we attempted to identify the causes of the increased vibration levels based on the measured vibration spectrum and the temperature distribution on the machine casing. On the basis of analysis results, the tested fluid-flow machine was qualified in the appropriate zone (defining the state of vibration) and identified the source of high levels of vibration.

Authors

Additional information

Category
Publikacja w czasopiśmie
Type
artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
Language
angielski
Publication year
2013

Source: MOSTWiedzy.pl - publication "Dynamic state assessment of the water turbine with the power of 600 kW" link open in new tab