Vortex separators are locally applied for waste water treatment in different systems - from storm waste water sewerage to water treatment in fish ponds. However, the methods for separator design presented in the literature are questionable. The paper presents two simple and functional criteria that were employed to construct a laboratory test stand. The test results gave positive feed back on the efficiency of vortex separators.