In this article there is a presentation of the analysis of the polarizing voltage shape influencing dynamic properties of voltammetric electrodes when on their surface reversible reaction takes place in the time domain. The electrode polarization with linearly increasing voltage and with a square component, was analyzed. The analysis that were conducted showed that the voltammetric electrode behaves like a first order transducer. Its dynamic properties in the time domain are defined by sensitivity and time constant. The results of the simulations show that these properties are determined by parameters of the voltage polarizing a voltammetric electrode.
Authors
Additional information
- DOI
- Digital Object Identifier link open in new tab 10.1109/coe.2018.8435160
- Category
- Aktywność konferencyjna
- Type
- publikacja w wydawnictwie zbiorowym recenzowanym (także w materiałach konferencyjnych)
- Language
- angielski
- Publication year
- 2018