Performance of the hydrostatic high-pressure drive systems is affected by the changes of working fluid’s volume. Presence of air bubbles in the fluid cause this problem to be even more serious. To study this phenomenon precise measurements of fluid’s bulk modulus are necessary. Differ-ent measurement methods are applied, but they are either limited to low pressure range or give inaccurate results. To solve the problem the new measurement device was built. It allows to directly measure volume changes of both pure fluid or fluid-air mixture within the wide pressure and temperature range. Both adiabatic and isothermal module may be determined, the tested fluid may be pure or aerated.. Measurements of different fluids were made including vegetable oils (rapeseed, sunflower and linseed), mineral oil and synthetic oil.
Authors
Additional information
- DOI
- Digital Object Identifier link open in new tab 10.1007/978-3-030-59509-8_38
- Category
- Publikacja monograficzna
- Type
- rozdział, artykuł w książce - dziele zbiorowym /podręczniku w języku o zasięgu międzynarodowym
- Language
- angielski
- Publication year
- 2021