Dead time effects compensation strategy by third harmonic injection for a five-phase inverter

This paper proposes a method for compensation of dead-time effects for a fivephase inverter. In the proposed method an additional control subsystem was added to the field-oriented control (FOC) scheme in the coordinate system mapped to the third harmonic. The additional control loop operates in the fixed, orthogonal reference frame ( α - β coordinates) without the need for additional Park transformations. The purpose of this method is to minimize the dead-time effects by third harmonic injection in two modes of operation of the FOC control system: with sinusoidal supply and with trapezoidal supply. The effectiveness of the proposed control method was verified experimentally on a laboratory setup with a prototype five-phase interior permanent magnet synchronous machine (IPMSM). All experimental results were presented and discussed in the following paper.

Authors

Additional information

DOI
Digital Object Identifier link open in new tab 10.24425/aee.2024.148854
Category
Publikacja w czasopiśmie
Type
artykuły w czasopismach dostępnych w wersji elektronicznej [także online]
Language
angielski
Publication year
2024

Source: MOSTWiedzy.pl - publication "Dead time effects compensation strategy by third harmonic injection for a five-phase inverter" link open in new tab