Bridge structures undergo thorough examination during test loading before they come into use. The aim of the examination is to check the correctness of the working structure and construction design assumptions. Test loading on the bridge is preceded by examination specification. This paper describes computational model and test loading results carried out during examibation of the bridge over the Vistula within the bypass of Puławy - the biggest structure of that type in Poland. The examination was conducted by the team from Department of Structure Mechanics and Bridges of Gdańsk University of Technology.
Autorzy
Informacje dodatkowe
- Kategoria
- Publikacja monograficzna
- Typ
- rozdział, artykuł w książce - dziele zbiorowym /podręczniku w języku o zasięgu międzynarodowym
- Język
- angielski
- Rok wydania
- 2009
Źródło danych: MOSTWiedzy.pl - publikacja "Test loading of the longest span arch bridge in Poland" link otwiera się w nowej karcie