This paper presents the results of laboratory research the pressure drop in the internal channels of unloaded satellite pump pumping tap water. Also shows the characteristics of the increase of pressure in the working chamber of the pump. It has been shown that after reaching cavitation, increase pump speed will increase in torque. This is the moment of inertia caused by the increase of the operating mechanism and the liquid contained in the working chambers. The results of laboratory research the pressure drop in the internal channels compared with numerical calculation. The paper also presents the unloaded pump power balance.