the paper deals with the problem of early leak detection in transmission pipelines. First we present the derivation of state-space equations of the flow process in the pipelines. This description is then aggregated in order to obtain a principal model. Next, the problem of process model parameterization is addressed, taking into account the maximization of a model stability margin. The location of the maximum is determined using optimization methods and curve fitting techniques. In such a way an optimal process parameterization is obtained. A simplified state-space model is then derived based on diagonal approximation, referred to as the analytic model (AMDA). Finally, the useful properties of the developed model are analyzed, including the speed and accuracy of an applied inverse matrix.
Autorzy
Informacje dodatkowe
- DOI
- Cyfrowy identyfikator dokumentu elektronicznego link otwiera się w nowej karcie 10.1007/978-3-319-23180-8_17
- Kategoria
- Publikacja monograficzna
- Typ
- rozdział, artykuł w książce - dziele zbiorowym /podręczniku w języku o zasięgu międzynarodowym
- Język
- angielski
- Rok wydania
- 2016