The paper is devoted to stability analysis of different models of steel cold formed silo column. The steel cylindrical silos are often composed of corrugated walls and vertical open-sectional columns uniformly placed along the silo circumference. Both the whole 3D silo, a simplified model consisting of one column with a part of the silo walls, and a single column resting on elastic foundation provided by the silo walls were analyzed. Linear buckling analyses were carried out using commercial FE package ABAQUS. Axisymmetric and non-axisymmetric loads imposed by a bulk solid following Eurocode 1 were considered. The calculated buckling loads of 1D column model were compared with the permissible one given by Eurocode 3 and with results found for the whole silo and a single column on elastic foundation modeled by shell elements.
Autorzy
Informacje dodatkowe
- Kategoria
- Publikacja w czasopiśmie
- Typ
- artykuły w czasopismach recenzowanych i innych wydawnictwach ciągłych
- Język
- angielski
- Rok wydania
- 2016
Źródło danych: MOSTWiedzy.pl - publikacja "Buckling Analysis of Cold Formed Silo Column" link otwiera się w nowej karcie