Repozytorium publikacji - Politechnika Gdańska

Ustawienia strony

english
Repozytorium publikacji
Politechniki Gdańskiej

Treść strony

Load testing of a suspended footbridge in Radom (Poland)

The footbridge in Radom is a suspended bridge of an interesting architectural form. The structure was de-signed for 4 kN/m2 of crowd loading. Dynamic calculations were not included in the design. The structure’s acceptance tests took place on the 14th of October 2016. The behaviour of the footbridge in static testing met the expectations. Unfortunately, as a result of dynamic tests, dangerous behaviour of the footbridge was revealed. A rhythmic jump test induced deck vibrations with an acceleration of 4.51 m/s2. For this reason, a newly built object has not been approved for use and the structure requires installation of additional damping devices. The article presents analyses of the load test design stage, describing performed tests and their re-sults, showing the comparison of theoretical and measured parameters and further indicating the improper dynamic behaviour which prevented the structure usage until the repair.

Autorzy

Informacje dodatkowe

DOI
Cyfrowy identyfikator dokumentu elektronicznego link otwiera się w nowej karcie 10.1201/9781315166605-100
Kategoria
Publikacja monograficzna
Typ
rozdział, artykuł w książce - dziele zbiorowym /podręczniku w języku o zasięgu międzynarodowym
Język
angielski
Rok wydania
2018

Źródło danych: MOSTWiedzy.pl - publikacja "Load testing of a suspended footbridge in Radom (Poland)" link otwiera się w nowej karcie

Portal MOST Wiedzy link otwiera się w nowej karcie