The Organic Flash Cycle (OFC) is suggested as a vapor power cycle that could potentially improve the efficiency of utilization of the heat source. Low and medium temperature finite thermal sources are considered in the cycle. Additionally the OFC’s aim is to reduce temperature difference during heat addition. The study examines 2 different fluids. Comparisons are drawn between the OFC and an optimized basic Organic Rankine Cycle (ORC). Preliminary results show that ethanol and water are better suited for the ORC and OFC due to higher power output. Results also show that the single flash OFC achieves better efficiencies than the optimized basic ORC. Although the OFC improves the heat addition exergetic efficiency, this advantage was negated by irreversibility introduced during flash evaporation.
Autorzy
- prof. dr hab. inż. Dariusz Mikielewicz link otwiera się w nowej karcie ,
- dr hab. inż. Jan Wajs link otwiera się w nowej karcie ,
- prrof. dr hab. inż. Jarosław Mikielewicz
Informacje dodatkowe
- DOI
- Cyfrowy identyfikator dokumentu elektronicznego link otwiera się w nowej karcie 10.24425/119100
- Kategoria
- Publikacja w czasopiśmie
- Typ
- artykuł w czasopiśmie wyróżnionym w JCR
- Język
- angielski
- Rok wydania
- 2018
Źródło danych: MOSTWiedzy.pl - publikacja "Alternative cogeneration thermodynamic cycles for domestic ORC" link otwiera się w nowej karcie