Repozytorium publikacji - Politechnika Gdańska

Ustawienia strony

english
Repozytorium publikacji
Politechniki Gdańskiej

Treść strony

Frequency Diagnostics of Transformer Insulating Parameters

In the article is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers, mainly by progressive frequency method – dielectric spectroscopy. In the 1-st part of the article is described base theory about measurement and diagnostics insulating part (oil and paper) of power transformers. In the 2-nd part of article is described measuring method of insulating frequency diagnostics - frequency domain spectroscopy (FDS). This method is used for analysis insulating condition of highvoltage equipment with insulating oil-paper. In the 3-st part of article is described measuring time method of insulating diagnostics - return voltage measurement (RVM). This method is used for analysis of condition of paper moisture of high-voltage equipment. The both measuring methods are unique in terms of analysis of insulating system of oil power transformers. In comparison with other methods, the RVM and FDS methods it is possible comparison and evaluate the moisture state of the dielectric paper of the power transformer with high reliability and accurate. Their reliability in determining moisture in paper was shown by determining the same result (3.5%) on the same measured distribution transformer.

Autorzy

Informacje dodatkowe

DOI
Cyfrowy identyfikator dokumentu elektronicznego link otwiera się w nowej karcie 10.1109/diagnostika49114.2020.9214676
Kategoria
Aktywność konferencyjna
Typ
publikacja w wydawnictwie zbiorowym recenzowanym (także w materiałach konferencyjnych)
Język
angielski
Rok wydania
2020

Źródło danych: MOSTWiedzy.pl - publikacja "Frequency Diagnostics of Transformer Insulating Parameters" link otwiera się w nowej karcie

Portal MOST Wiedzy link otwiera się w nowej karcie