The influence of thin gold electrodes on the electrical measurements of glasses at high temperatures was studied using impedance spectroscopy. The impedance was measured several times over a wide frequency range from 10 mHz to 1 MHz and the temperature ranged from 213 to 673 K under air and nitrogen atmospheres. The results showed a drop in the conductivity of more than an order of magnitude at a temperature around 603 K during heating. An additional relaxation process was found at the low-frequency region. The occurred process was correlated with the thermal disintegration of the gold nano-layer used as an improvement in the electrical contact. The possible ambiguous interpretation of high-temperature impedance spectra was presented as a consequence of performing the electrical measurements only during heating or cooling while using unstable thin gold electrodes. Moreover, a possible solution to this problem was proposed.