An optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency battery charger for electric vehicles. The convergent approach to TPS mode selection also reduces the numerous cases for small-signal analysis through general average modeling. After verifying the small-signal models under various voltage transfer ratios and load conditions to verify the stability, a converter prototype with a rated power of 15 kW is built and tested. Thus, a peak efficiency of 97.7% can be achieved.
Autorzy
- Shih-hao Kuo,
- Huang-Jen Chiu,
- Che-Wei Chiang,
- Ta-Wei Huang,
- Yu-Chen Chang,
- Serafin Bachman,
- Szymon Piasecki,
- dr hab. inż. Marek Jasiński,
- dr hab. inż. Marek Turzyński link otwiera się w nowej karcie
Informacje dodatkowe
- DOI
- Cyfrowy identyfikator dokumentu elektronicznego link otwiera się w nowej karcie 10.3390/en17020354
- Kategoria
- Publikacja w czasopiśmie
- Typ
- artykuły w czasopismach
- Język
- angielski
- Rok wydania
- 2024