In this article, an improved single-phase dual-ground transformerless inverter topology is proposed. The proposed inverter topology is able to generate a 7L output voltage waveform with a boosting factor of 1.5. The increased voltage gain of the proposed topology does not result in increased voltage stress on the components. The proposed structure requires 8 IGBTs, one diode, and three switched capacitors (SCs) with self-voltage balancing. To further reduce leakage current, the proposed topology employs a dual ground configuration between the source's negative terminal and the grid's neutral. A comparison with recent seven-level inverter topologies is included to emphasize the proposed topology's benefits. After confirming the viability of the proposed topology through simulation using the Simulink platform, an experimental validation using 1 kW is carried out using a prototype setup, and the results are measured.
Autorzy
- dr hab. inż. Atif Iqbal,
- Jagabar Sathik M,
- Gopinath Np,
- prof. dr hab. inż. Jarosław Guziński link otwiera się w nowej karcie
Informacje dodatkowe
- DOI
- Cyfrowy identyfikator dokumentu elektronicznego link otwiera się w nowej karcie 10.1109/sefet61574.2024.10718031
- Kategoria
- Aktywność konferencyjna
- Typ
- publikacja w wydawnictwie zbiorowym recenzowanym (także w materiałach konferencyjnych)
- Język
- angielski
- Rok wydania
- 2024