A case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system against stray currents was proposed and designed at the Department of Electrochemistry, Corrosion and Materials Engineering, Gdansk University of Technology. Coupon technique measurements and potential measurements were performed to verify the effectiveness of the protection system.
Authors
Additional information
- DOI
- Digital Object Identifier link open in new tab 10.3846/bjrbe.2015.02
- Category
- Publikacja w czasopiśmie
- Type
- artykuł w czasopiśmie wyróżnionym w JCR
- Language
- angielski
- Publication year
- 2015