his paper presents the ‘CPT 2012’ model incorporated into the AFNOR NF P94-262:2012-07, French standard for pile design fully compatible with Eurocode 7, to the wider Polish audience. The bearing capacity of three reference columns for Vistula Marshlands have been calculated according to ‘CPT 2012’ model and AFNOR recommendations. Then, the design resistances have been compared with ultimate column bearing capacity measured during static load tests conducted on reference columns. The results of comparison are discussed and the discrepancies between measured and calculated bearing capacities are shortly commented.
Authors
Additional information
- DOI
- Digital Object Identifier link open in new tab 10.1051/matecconf/201926204001
- Category
- Aktywność konferencyjna
- Type
- publikacja w wydawnictwie zbiorowym recenzowanym (także w materiałach konferencyjnych)
- Language
- angielski
- Publication year
- 2019