State and control system variables sensitivity to rotor asymmetry in the induction motor drive

The aim of this paper is to undertake analysis and comparison of the closed-loop and sensorless control systems sensitivity to the broken rotor for diagnostic purposes. For the same vector control system induction motor drive analysis concerning operation with the asymmetric motor, broken rotor fault handling and operation were investigated. Reliability, range of stable operation, fault symptoms and application of diagnosis methods based on control system variables utilization was analyzed. Asymmetric IM motor drive handling and diagnosis. Broken rotor rangediagnosis inconsistency using the popular MCSA method should be considered in the closed-loop and sensorless control system of the induction motor drive. Depending on the IM motor drive applicationand the operation requirements the results can be used for asymmetric machine proper handling, choosing proper control system structure and control system variables for rotor fault early diagnosis